Plumbing and heating
Description
Hi i'am a Fully Qualified Gas Safe Registered engineer Charlie Brenland
( Gas Safe Number 551745)
will repair Vaillant Ecotec Turbomax Ecomax Worcester Bosch Junior or Greenstar CDI, Main combi , Baxi Potterton profile, performa, suprima Keston C40 C36, Ideal Icos – Ideal isar Mexico Classic boiler repair specialist throughout London – central London and anywhere within the M25
To book an engineer - Call now
07535558680 ( no marketing or sales calls please)
I specialised in repair service and fault finding the above boilers. IF your Vaillant , Worcester Bosch, Main, Baxi, Potterton, Keston or Ideal icos isar Mexico or classic or any other boiler which you may have not working call 07535558680 to book our Service and get your boiler fixed.
Iam a specialised Gas Engineers who is well trained to service and repair your ideal icos and isar boiler without no delay – since i keep most spare parts for the boiler, i can offer you hassle free quick boiler repair service experience.
I'am are able to fix all the faults with Vaillant boilers such as :-
F22-F23-F24-F75= Pump, PCB or water pressure problem
F28-F29-F62= Gas supply - Gas control or pcb faults
F0-F1-F10-F11-F13-F20-F63-F64-F65-F71-F73-F74-F76 - sensor or Heat Exchanger
F77-F78-Con - Condensate or wiring connection problem.
Main boiler flame failure light flashing -leaking or no hotwater
Baxi boiler red light flashing - leaking or no heating
Performa boiler flashing red or no pressure
Suprima boiler going to lock out red or not working at all
Keston boiler Displaying E code:-
E00-E02= Gas , condensate or flame control problem
E03-E04-E44 = Low pressure or power interrupped
E11-E12 = Electrronic error or power interrupted
E18-E19-E25-E30= Water overheating
E28-E30-E31-E32-E36-E37 = Fan , PCB or sensor faulty
Below is the display when Ideal icos boiler is working normally:-
0 = Standby, no demand for heat present.
c = Boiler is active for central heating.
Below is the display when Ideal isar boiler is working normally:-
0 = Standby, no demand for heat present.
c = Boiler is active for central heating
d = Boiler is active for domestic hot water.
t= Boiler is heating up the plate heat exchanger.
Below is the display when Ideal icos or isar has developed a fault on it:-
H =Boiler is in lockout for a specific error.
L = Boiler is in lockout for a specific error. ( Display will be
blinking, alternating with a number or letter to show which
error is detected. )
Most Common faults with this boilers:-
1. The boiler display is not displaying anything and boiler is eerily quiet!
2. Alternating lockout codes such as :- L-F , L-E or L-E, L-A, L-8, H-1, H-2, H-3, H-4, H-F, H-n
3. Boiler comes on for short period and goes out displaying one of the above code.
4. Boiler noisy and eventually fail to ignite and give heat.
5. Boiler is not heating the hot water or heating hot enough as it used to be.
6. No central Heating – or no hot water.
7. Central heating is working ok but no hotwater.
8. Boiler leaking out water.
9. H =Boiler is in lockout for a specific error.
10. L = Boiler is in lockout for a specific error. ( Display will be
blinking, alternating with a number or letter to show which
error is detected. )
A bit more about me and what I do
10 years Experience / 24-7 emergency call out /
NVQ qualified / City and guilds qualified / gas safe registered / good contacts within the plumbing industry / free written on the site quotations /
Leaking pipes boilers radiators Bath sinks drainpipes gutters
Faultfinding boiler replacements new design and boiler installation
gas safety inspections annual services maintenance plans
Gas fires gas cookers
Gas boilers gas water heaters
I can repair maintained and serviced them all gas safe registered for 11 years